Metrel MD 9070 Insulation and Continuity Multimeter
Metrel MD 9070 Insulation and Continuity Multimeter
SKU:MET9070M
Couldn't load pickup availability

Overview
The Metrel MD 9070 is a high accuracy insulation and continuity multimeter designed for use in a CAT IV / 600 V environment. Its dual digital display provides all the necessary data to the operator, while its compact size ensures single-handed operation. The instrument features a built-in VFD capability for measuring true RMS values in accordance with frequency, along with the ability to perform PI/DAR measurements and diode tests. The Metrel MD 9070 boasts a wide array of additional features, including data hold, memory functions, min/max recording, differential measurements, auto power off, auto-ranging, frequency filtering, a lock feature, reset, relative functions, and more.
Applications
Ideal for:
- Insulation and earth continuity testing for preventive maintenance
- High-level industrial testing
- High-level electronic fault finding
- Field servicing
- Heavy-duty electrical testing
Measures
- TRMS measurement
- Insulation resistance measurement
- Earth continuity measurement
- Resistance measurement
- Diode test
- Mains supply frequency measurement
Features and Specifications
- TRMS: Accurate readings on sinusoidal and non-sinusoidal signals.
- VFD: Capable of measuring true values in accordance with frequency.
- Auto-ranging: Allows switching between auto and manual ranging.
- Temperature Measurement: Measures T1, T2, and T1 + T2 temperatures in Celsius and Fahrenheit.
- Lead Alert: Indicates incorrect lead connections.
- Relative Zero Mode: Compares the difference between signals or removes background noise.
- MAX/MIN/AVG: Records maximum, minimum, and average values.
- Data Hold: Freezes the display for later viewing.
- Peak Hold: Captures instantaneous peak values.
- PC Link: Downloads test results to a computer via optional PC software.
Specifications
- TRMS AC Voltage: (50 Hz ~ 5 kHz) 6.000 V … 1000 V from ±(1.0% of reading + 3 digits) to ±(4.0% of reading + 5 digits)
- VFD AC Voltage: (10 Hz ~ 440 Hz) 600.0 V from ±(4.0% of reading + 5 digits) to ±(7.0% of reading + 5 digits)
- DC Voltage: 6.000 V … 1000 V from ±(0.2% of reading + 3 digits) to ±(0.3% of reading + 3 digits)
- Ohms: 600.0 Ω … 60.00 MΩ from ±(0.9% of reading + 2 digits) to ±(3.0% of reading + 6 digits)
- Audible Continuity Tester: Between 20 Ω and 200 Ω, Response time < 30 ms
- Diode Tester: 2.000 V ±(1.5% of reading + 4 digits)
- Earth Continuity Test: 0.015 Ω … 21.99 Ω ±(1.5% of reading + 3 digits)
- Hz Line Level Frequency: 10 Hz … 440 Hz ±(0.02% of reading + 4 digits)
- Insulation Resistance: 50 V … 1000 V from ±(1.5% of reading + 5 digits) to ±(10.0% of reading + 5 digits)
- Overload Protection: Insulation Resistance 0.4 A / 1 kV, IR 30 kA or better; Earth Continuity Test: 0.25 A / 1 kV, IR 30 kA or better; V: 1100 Vrms; mV, Ω & Others: 1000 Vrms.
- Power Supply: Four Alkaline AA batteries (IEC LR6).
- Physical Dimensions: 208 x 103 x 64.5 mm (with holster).
- Weight: 635 g (with holster).
Included
Standard manufacturer warranty: 1 Year
- Multimeter MD 9070 with rubber holster
- Test lead with probe (2 pcs)
- Insulated crocodile clip (2 pcs)
- Insulation/continuity test lead with probe (1 pcs)
- 1.5 V AA battery
BUYING GUIDE
Need help with find the right option?
Our buying guide takes the guess work out of finding the perfect tester for your needs