{"product_id":"metrel-mi-3136-instaltest-combo-xc-advanced-kit","title":"Metrel MI 3136 InstalTest Combo XC – Advanced Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMetrel MI 3136 InstalTest COMBO XC Advanced Installation Testing Kit\u003c\/strong\u003e combines essential electrical installation tests with a modern colour touchscreen and onboard result storage. Suitable for installation verification to AS\/NZS 3000 and testing to AS\/NZS 3017, it brings insulation resistance, continuity, RCD testing, loop impedance and phase rotation testing together in one portable instrument.\u003c\/p\u003e\n\u003cp\u003eThis Advanced Kit adds a padded carrying bag, remote test probe, switchboard resistor box, 4m trailing earth lead and non-contact voltage detector to the standard instrument package. Our TTS package also includes a USB-C charger, 100 switchboard test tags and 200 RCD test tags.\u003c\/p\u003e\n\u003cp\u003eThe 4.3-inch touchscreen makes selecting tests, viewing results and organising records easy. Preset and adjustable PASS\/FAIL limits help assess measurements, while automatic test sequences reduce repetitive setup when testing multiple circuits or RCDs.\u003c\/p\u003e\n\u003cp\u003eThe instrument uses the same operating software as the other Metrel testers of this generation including simple formats for organising site structures. These structures can be configured on the tester at the time of testing or uploaded prior to site visit from a Windows PC.\u003c\/p\u003e\n\u003cp\u003eThe MI 3136 features Autotest sequences with built-in preconfigured PASS\/FAIL thresholds for Australian installation testing to AS\/NZS 3000. \u003c\/p\u003e\n\u003cp\u003eThe socket testing function checks earth continuity, polarity and correct circuit connections. With the included A1195 resistor box positioned at the switchboard, it supports socket testing without a lengthy trailing earth lead. An optional A1532 XA EVSE adaptor extends the tester's capabilities to compatible electric vehicle charging stations.\u003c\/p\u003e\n\u003cp\u003eA rechargeable lithium-ion battery, USB-C charging, Bluetooth and Wi-Fi connectivity support everyday testing and data management. Metrel ES Manager BASIC software is included, with additional reporting and cloud functions available through optional licences.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This product is an installation tester. It is not a portable appliance tester and is not intended for routine appliance test and tag work.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe MI 3136 supports the following installation verification and electrical testing applications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage and frequency\u003c\/li\u003e\n\u003cli\u003ePhase rotation\u003c\/li\u003e\n\u003cli\u003eResistance of earth connections and equipotential bonding\u003c\/li\u003e\n\u003cli\u003eLow-current continuity\u003c\/li\u003e\n\u003cli\u003eInsulation resistance\u003c\/li\u003e\n\u003cli\u003eSocket polarity and correct circuit connections\u003c\/li\u003e\n\u003cli\u003eFault loop impedance and prospective fault current\u003c\/li\u003e\n\u003cli\u003eLine impedance and prospective short-circuit current\u003c\/li\u003e\n\u003cli\u003eRCD trip time, ramp current and automatic testing\u003c\/li\u003e\n\u003cli\u003eContact voltage\u003c\/li\u003e\n\u003cli\u003eVoltage drop\u003c\/li\u003e\n\u003cli\u003eThree-wire earth resistance testing with optional accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eInsulation Resistance\u003c\/h3\u003e\n\u003cp\u003eSelectable test voltages of 50V, 100V, 250V, 500V and 1000V DC, with automatic discharge after testing.\u003c\/p\u003e\n\u003ch4\u003eNominal Voltages: 50V, 100V \u0026amp; 250V DC\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (MΩ)\u003c\/th\u003e\n\u003cth\u003eResolution (MΩ)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.00 ... 19.99\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.0 ... 99.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±(10% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100.0 ... 199.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±(20% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eNominal Voltage: 500V DC\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (MΩ)\u003c\/th\u003e\n\u003cth\u003eResolution (MΩ)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.00 ... 19.99\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.0 ... 199.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 ... 999\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e±(10% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eNominal Voltage: 1000V DC\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (MΩ)\u003c\/th\u003e\n\u003cth\u003eResolution (MΩ)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.00 ... 19.99\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.0 ... 199.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 ... 999\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eIndicative only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eVoltage During Insulation Testing\u003c\/h3\u003e\n\u003cp\u003eDisplays the applied insulation test voltage. This is separate from the general voltage measurement function.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (V)\u003c\/th\u003e\n\u003cth\u003eResolution (V)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 ... 1200\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e±(3% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eResistance (R LOWΩ)\u003c\/h3\u003e\n\u003cp\u003eMeasures protective conductor and equipotential bonding resistance using a minimum 200mA test current into a 2Ω load. Automatic polarity reversal and test lead compensation support reliable low-resistance measurements.\u003c\/p\u003e\n\u003ch4\u003eMeasuring Range\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (Ω)\u003c\/th\u003e\n\u003cth\u003eResolution (Ω)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.00 ... 19.99\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±(3% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.0 ... 199.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200 ... 1999\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRCD Testing\u003c\/h3\u003e\n\u003ch4\u003eGeneral Data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSupported RCD types include AC, A, F, B and B+\u003c\/li\u003e\n\u003cli\u003eNominal residual current settings from 6mA to 1000mA, depending on the selected protective device\u003c\/li\u003e\n\u003cli\u003eSine-wave, pulsed and DC test currents\u003c\/li\u003e\n\u003cli\u003eTest current starting polarity: 0°, 180° or both\u003c\/li\u003e\n\u003cli\u003eTrip time, trip current and contact voltage measurements\u003c\/li\u003e\n\u003cli\u003eAutomatic RCD test sequences\u003c\/li\u003e\n\u003cli\u003eSelectable AS\/NZS 3017 test settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAvailable test currents, multipliers and test durations depend on the selected RCD type and test configuration.\u003c\/p\u003e\n\u003ch4\u003eTrip-out Time\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (ms)\u003c\/th\u003e\n\u003cth\u003eResolution (ms)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.0 ... 40.0\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±1ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40.1 ... 999.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±3ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 ... 1999\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e±3ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 ... 10000\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e±10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eTrip-out Current\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.1 ... 99.9mA\u003c\/td\u003e\n\u003ctd\u003e0.1mA\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ... 999mA\u003c\/td\u003e\n\u003ctd\u003e1mA\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.00 ... 1.10A\u003c\/td\u003e\n\u003ctd\u003e10mA\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSocket Test\u003c\/h3\u003e\n\u003cp\u003eThe Australian socket test function combines earth continuity, polarity and correct connection checks into a single push-button sequence, with clear PASS\/FAIL results.\u003c\/p\u003e\n\u003cp\u003eThe included A1195 resistor box connects at the switchboard to support testing at socket outlets without a trailing earth lead. This accessory is part of the Advanced Kit supplied here.\u003c\/p\u003e\n\u003ch3\u003eFault Loop Impedance\u003c\/h3\u003e\n\u003ch4\u003eWithout RCD Protection\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (Ω)\u003c\/th\u003e\n\u003cth\u003eResolution (Ω)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.00 ... 9.99\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±(3% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.0 ... 99.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±(3% of reading + 3 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ... 999\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e±(10% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 ... 9990\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e±(10% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eWith RCD Protection – Standard Test Current Mode\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (Ω)\u003c\/th\u003e\n\u003cth\u003eResolution (Ω)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.00 ... 9.99\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.0 ... 99.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±(5% of reading + 10 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ... 999\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e±(10% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 ... 9990\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e±(10% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eProspective Fault Current (Calculated Value)\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (A)\u003c\/th\u003e\n\u003cth\u003eResolution (A)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.00 ... 9.99\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003eDependent on loop impedance measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.0 ... 99.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003eDependent on loop impedance measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ... 999\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eDependent on loop impedance measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 ... 9990\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eDependent on loop impedance measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 ... 23000\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003eDependent on loop impedance measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eVoltage, Frequency \u0026amp; Phase Rotation\u003c\/h3\u003e\n\u003ch4\u003eVoltage\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eResult type: True RMS\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring of voltages between the connected test terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (V)\u003c\/th\u003e\n\u003cth\u003eResolution (V)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 ... 550\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e±(2% of reading + 2 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFrequency\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring Range (Hz)\u003c\/th\u003e\n\u003cth\u003eResolution (Hz)\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e14.0 ... 499.9\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±(0.2% of reading + 1 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePhase Rotation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNominal system voltage: 100V ... 550V AC\u003c\/li\u003e\n\u003cli\u003eNominal frequency: 14Hz ... 500Hz\u003c\/li\u003e\n\u003cli\u003eDisplays phase sequence as 1.2.3 or 3.2.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOvervoltage Category: 600V CAT III \/ 300V CAT IV\u003c\/li\u003e\n\u003cli\u003eProtection Degree: IP40\u003c\/li\u003e\n\u003cli\u003eProtection Class: Double insulation\u003c\/li\u003e\n\u003cli\u003eDisplay: 4.3-inch colour TFT capacitive touchscreen, 480 x 272 pixels\u003c\/li\u003e\n\u003cli\u003ePower Supply: 7.2V, 5200mAh rechargeable lithium-ion battery pack\u003c\/li\u003e\n\u003cli\u003eCharging: USB Type-C Power Delivery\u003c\/li\u003e\n\u003cli\u003eTypical Battery Operation: 14 hours\u003c\/li\u003e\n\u003cli\u003eConnectivity: USB-C, Bluetooth and Wi-Fi\u003c\/li\u003e\n\u003cli\u003eResult Storage: microSD-based memory\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: 0°C to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum Operating Humidity: 90% RH, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMeasurement categories vary with the connected leads and accessories. Refer to the instrument manual for full specifications and operating conditions.\u003c\/p\u003e\n\u003ch2\u003eResult Storage \u0026amp; Reporting\u003c\/h2\u003e\n\u003cp\u003eStore measurements against organised installation records using the onboard Memory Organizer. Saved results can be transferred to Metrel ES Manager for further processing and record keeping.\u003c\/p\u003e\n\u003cp\u003eThe standard set includes a Metrel ES Manager BASIC licence. Advanced reporting and cloud workflows require the applicable MESM PRO and Metrel Cloud licences.\u003c\/p\u003e\n\u003ch2\u003eContents\u003c\/h2\u003e\n\u003cp\u003eThis package comprises the MI 3136 standard instrument set, the Advanced Kit accessories and the additional consumables and charger supplied by TTS.\u003c\/p\u003e\n\u003ch3\u003eMI 3136 Instrument and Standard Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMetrel MI 3136 InstalTest COMBO XC instrument\u003c\/li\u003e\n\u003cli\u003eRechargeable lithium-ion battery pack\u003c\/li\u003e\n\u003cli\u003e3 x Test probes: brown, blue and green\u003c\/li\u003e\n\u003cli\u003e3 x Crocodile clips: brown, blue and green\u003c\/li\u003e\n\u003cli\u003eThree-wire test cable, 1.5m\u003c\/li\u003e\n\u003cli\u003eMains measuring cable, 1.5m\u003c\/li\u003e\n\u003cli\u003eUSB Type-C cable\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eShort instruction manual\u003c\/li\u003e\n\u003cli\u003eInstruction manual, available to download\u003c\/li\u003e\n\u003cli\u003eMetrel ES Manager software with BASIC licence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Kit Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA1551 large padded carrying bag\u003c\/li\u003e\n\u003cli\u003eA1401 remote test probe for XC\/XD series\u003c\/li\u003e\n\u003cli\u003eA1195 resistor box for socket testing\u003c\/li\u003e\n\u003cli\u003eA1012 green trailing earth lead, 4m\u003c\/li\u003e\n\u003cli\u003eMD-106 non-contact voltage detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional Items Included by TTS\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUSB-C charger\u003c\/li\u003e\n\u003cli\u003e100 x switchboard test tags\u003c\/li\u003e\n\u003cli\u003e200 x RCD test tags\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOptional accessories:\u003c\/strong\u003e Earth resistance test set and A1532 XA EVSE adaptor are available separately.\u003c\/p\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cp\u003eManufacturer's warranty applies. Please contact us for warranty details.\u003c\/p\u003e","brand":"Metrel","offers":[{"title":"Default Title","offer_id":68296909455580,"sku":"PKGS3136","price":2854.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/7535\/3308\/files\/PKGS3136_STD_02.jpg?v=1794802416","url":"https:\/\/testandtagsupplies.com.au\/products\/metrel-mi-3136-instaltest-combo-xc-advanced-kit","provider":"Test and Tag Supplies","version":"1.0","type":"link"}