Overview:
This standard edition model includes Fixed and Portable RCD Testing (with built in Isolation), battery operation (for most Tests) and even a basic logging feature (optional software required).
Please note that this model does not feature the Bluetooth or Wifi connectivity of the Kyoritsu 6205 Pro.
- Large clear LCD display with unique colour change pass/fail backlight
- Both 250V and 500V DC insulation testing for all types of appliances
- Battery operation for portability (excluding leakage testing and RCD testing)
- Null feature for Earth Continuity tests for a variety of test leads and conditions
Applications:
Testing appliances and leads in accordance with the AS/NZS 3760:2010 and both portable and fixed RCD testing (fixed RCD CATII from GPO only).
Class 1 (Earthed Appliance) Tests
- Earth continuity test (Test current 200mA DC nominal)
- Insulation resistance test (250V or 500V)
- Leakage current test (100-253V/50Hz)
- Load current test (100-253V/50Hz)
Class 2 (Double Insulated Appliance) Tests
- Insulation resistance test (250V or 500V)
- Leakage current test (100-253V/50Hz)
- Load current test (100-253V/50Hz)
Extension Lead/IEC Lead Tests
- Earth continuity test (Test current 200mA DC nominal)
- Insulation resistance test (between Line/Neutral-Earth short, Line/Neutral)
- Leakage current test (100-253V/50Hz)
- Polarity test
RCD Tests - Fixed and Portable
- Fixed RCD (via Power Outlet) 10mA & 30mA
- Portable RCD (with Isolation) 10mA & 30mA
Features and Specifications
Mains Voltage Indication
- Display Range 30 – 270V
- Accuracy ±5V
Earth Continuity
- Measuring Range 0 – 20Ω
- Open Circuit Voltage 5V
- Measuring current 200mA DC (nominal)
- Accuracy ±3% of Reading ±5 Digits
Insulation Resistance
- Range 0.00-20.00MΩ
- Voltage 250V / 500V DC Selectable
- No Load Voltage 250V DC +20%,-0% / 500V DC +20%,-0%
- Short Circuit Current 1.5mA DC or less
- Accuracy ±2% of Reading ±3 Digits
Leakage Current
- Mains Voltage Range 100-253V/50Hz
- Measuring Range 0.10-20.00mA rms
- Accuracy ±3% of Reading ±5 Digits
Load Current
- Mains Voltage Range 100-253V/50Hz
- Measuring Range 0.10-20.00mA rms
- Accuracy ±10% of Reading ±5 Digits
RCD Tests
- Rated Voltage 230V -15% - +10%/50Hz
- RCD Trip Current 10mA/30mA
- Function x1 & x 5
- Test Duration (x 1) 0.0ms-500.0ms (x 5) 0.0ms-40.0ms
- Operating Time Accuracy ±2ms (<=40ms),±8ms (>40ms)
Power Source:
LR6(AA)(1.5V) × 6
230V AC Mains (For Leakage, Load and RCD Tests)
Applicable Standards:
IEC/EN61010-1 CAT II 300V
IEC/EN61010-2-030
IEC/EN61010-031
EN61326-2-2
AS/NZS3760
Included Accessories:
Retail box and packaging
7277 (Mains Lead)
7129A (Test lead with Alligator clip)
7161A (Flat Test Bar)
7276 (IEC Lead - Adaptor for Extension Cord)
9193 (Carrying Case)
8928 (Fuse[10A/250V])
9121 (Shoulder Strap)
Buckle
LR6(AA) x 6
Instruction Manual
Optional Accessories:
8263-USB (USB cable with "KEW Report(software)")
7275 (Printer cable:Mini Din 6pin-D-sub 9pin)
7248 (Test lead with Alligator Clip and Flat Test Bar)
Standard Warranty:
1 Year