Overview:
A very highly specified programmable portable appliance tester with recording facilities.
The new Delta PAT 3309 BT from European manufacturer Metrel sets new standards in features for portable appliance testers.
This unique unit delivers the complete range of test facilities at a price impossible to ignore.
Not only does the Metrel DeltaPAT deliver the complete suite of test facilities, but incorporates RCD testing, power measurement, current leakage testing and the unit is both mains and battery operated for most tests.
This latest version now includes the internal Bluetooth feature offering out-of-the-box compatibility with Android devices*.
*Subject to compatibility requirements. PATLink for Android or APAT for Android software key purchase recommended.
Applications:
Testing appliances and leads in accordance with the AS/NZS 3760:2010 and RCD testing. Testing of hard wired appliances.
Tests
- Earth continuity test
- Insulation test
- Polarity test (ext leads + IEC leads)
- Current leakage (Differential, Touch and Substitute)
- RCD Testing (10mA and 30mA)
- Power and Voltage
Included accessories:
Retail box and packaging, 1 x Earth Test Lead, 6 x AA NimH Batteries, Mains lead, IEC lead, Manual, USB cable, RS232 cable, Calibration Certificate.
Standard warranty
1 Year
22 Auto Test Sequences |
Earthed Appliance Standard (Class 1)
Double Insulated Appliance Standard (Class 2)
Extension Leads, Power Boards and IEC Leads
Earthed Appliance Leakage (Class 1 Run Test)
Double Insulated Appliance Leakage (Class 2 Run Test)
Extension Leads, Power Boards and IEC Leads Leakage Test
Fixed 30mA RCD - fixed RCD CATII from GPO only.
Portable 30mA RCD
Earthed Appliance 250V test
Double Insulated Appliance 250V test
Extension Lead 250V test
Earthed Appliance Full (includes power measurement)
Double Insulated Appliance Full (includes power measurement)
Fixed 10mA RCD
Portable 10mA RCD
Auto 10mA RCD
Auto 30mA RCD
Auto 10mA Portable RCD
Auto 30mA Portable RCD
Encapsulated Earth
Earthed Clamp
Earth Clamp Lead
MIMS
|
Insulation resistance |
Range 0 – 199.9MΩ
Voltage 250V / 500V DC Selectable
Resolution 0.01MΩ
PASS/FAIL Threshold Programmable
Accuracy 5% ± 3 digits
|
Substitute leakage |
Range 0 – 9.9mA
Voltage 50V AC Selectable
Resolution 0.01mA
PASS/FAIL Threshold Programmable
Accuracy 5% ± 3 digits
|
Differential leakage – Class 1 Earthed Appliances |
Range 0 – 19.99mA
Resolution 0.01mA
Accuracy 5% ± 5 digits
PASS/FAIL Threshold Programmable
Test Duration Selectable
|
Touch leakage – Class 2 Dbl Insulated Appliances |
Range 0 – 7mA
Resolution 0.01mA
Accuracy 10% ± 5 digits
PASS/FAIL Threshold Programmable
Test Duration Selectable
|
RCD Testing |
Range 0 – 300ms
Resolution 0.1ms
Accuracy ± 3 ms
Angle 0 and 180 degrees
Test Duration Selectable
|
Apparent Power Measurement |
Range 0.0kVA – 4.0kVA
Resolution 0.1kVA
Test Duration Selectable
|
TRMS Voltage Measurement |
Range 80V – 300V
Resolution 1V
Accuracy 2% ± 2 digits
|
Polarity |
Voltage 50V AC
|
Power |
Voltage 6 x AA NiMh Batteries
|
Memory |
Records - 1500
Fields - Date, Time, Asset ID, Description, Test Results, Retest, Location
|
Communications |
Bluetooth (Android devices *), RS232 and USB
* App Unlock extra
|
Safety |